Texas Instruments 51X User Manual

Page 76

Advertising
background image

Error Message

Corrective Action

Keyboard Interface Error

Cycle Power to Notebook. If
problem persists, replace keyboard;
if problem persists, replace Main
Board.

Memory Size Mismatch

Enter and then exit the System
Configuration Setup in the Setup
utility.

Missing operating system

Correct the HDD type and reboot.
Refer to the specification label
pasted on the back side of the
notebook or attached to hard disk
drive.

Non-system disk or disk error. Replace
and strike any key when ready

Insert a system disk in drive A and
press any key

Pointing Device Error

Cycle Power to Notebook; if
problem persists, replace Touchpad.

Pointing Device Interface Error

Cycle Power to Notebook; if
problem persists, open up the
notebook and check the touchpad
cabling

Protected Mode Test Fail

Cycle power to Notebook

RAM BIOS Bad

Cycle power to Notebook

RAM Parity Error.

Cycle power to Notebook if problem
persists, replace Main Board
and/or DIMMs modules.

Real Time Clock Error

Press Ctrl-Alt-Esc to reconfigure
the system.

Video RAM BIOS Bad

Cycle power to Notebook

Table A-2 POST Checkpoint List

Checkpoint

No.

Description

D4h

Normal POST start

FCh

CMOS and BIOS ROM checksum test skip or
complete

01h

80286 register test in-progress

02h

CMOS write/read test in-progress or failure

03h

BIOS ROM checksum in-progress or failure

A-2 Error Messages