1 Pulse Trigger SYNC-RESET Picture Output Timing

*1: Externally input signal
*2: Exposure time is determined by the setting of the MODE SELECT switch. Refer to page 9.
*3: VD is generated after 0 to 1H following the completion of the exposure period and the

video is synchronized to this and output.

NOTE

When the next trigger is input before completion of the output of the video corresponding to
the trigger, there will be an effect on the video.

About 1.7

µ

s

Exposure completion

to 1H*

3

Exposure period*

2

VIDEO INDEX

VD OUT

Trigger*

1

262.5H

Negative polarity mode

Positive polarity mode

External Sync Operation

Shutter mode

At time of SYNC-NON

RESET mode

At time of SYNC-RESET
mode

At time of reset restart

At time of normal shutter

HD input

N

Y

N

Y

N

Y

Y

N

N

Y

Y

N

VD input

N

Y

Y

N

Y

Y

N

N

Y

N

Y

Note

Internal sync mode

External sync mode

Only V reset is applied due to VD input.
Normally not used.

HD is synchronized to external, but
video is not output because there is no
VD input. Normally not used.

Internal sync mode. The presence of VD
is ignored, and after a specified time
after a trigger input, V reset is applied.

HD is synchronized to external. The pres-
ence of VD is ignored, and after a specified
time after a trigger input, V reset is applied.

HD is synchronized to external. Video is
output due to VD input.

HD is synchronized to the inside of the
camera. Video is output due to VD input.

Video is not output because there is no
VD input. Normally not used.

Internal sync mode

External sync mode

HD is synchronized to external. Normally
not used.

Disabled

Either Y or N is permitted.