Table 2.1 PM104 Pin Number and I/O Functions

IC3 PIN#

PM104 Microcontroller Description (IC3)

HE104 Function or Connection

Battery Charger Function

1

PM104 Supply Voltage

HE104 Supply Voltage

2

Common

Common

3

PC0 (PC out)

Connector CN4-3

4

PCI (Pc in)

Connector CN4-4

5

plus5V input/output

No connection

6

Reset

No connection

7

P0 (Input/Output Pin 0)

Input Voltage Status

8

P1 (Input/Output Pin 1)

HE104 On/Off Control

HE104 On/Off control

9

P2 (Input/Output Pin 2)

Connector CN6-8

Analog/Digital Chip Select

10

P3 (Input/Output Pin 3)*

Int2, Connector CN6-7*

Spare* Input/Output

11

P4 (Input/Output Pin 4)

Connector CN6-6

Data Input/Output Line

12

P5 (Input/Output Pin 5)

Connector CN605

Data Clock

13

P6 (Input/Output Pin 6)*

Int1, Connector CN6-4*

Spare* Input/Output

14

P7 (Input/Output Pin 7)

Connector CN6-3

Analog Current Limit


*If Interrupt function is not used, this PM104 line can be used for general purpose Input/Output.

2.9 Low Input Alarm

This output signals the Power Management circuit (PM104) or external circuitry that main input power
has failed. The Low Input Alarm signal has a 100K current limiting resistor in a series.

If the PM104 is not installed, then external circuitry can access the Low Input Alarm output on
connector IC3-7.