30

Let Bat1_chrg = 0
Main_Batt1:
Low PSU_OnOff

‘Just making sure PSU stays on!

If Bat1_Chrg = 1 then Batt_Trickle

is battery already charged?

Goto Bat_Chrg



Batt_Trickle:
‘debug “trickle”
gosub Chk_Pwr
let D1 = 0
let D0 =0
gosub Convert

‘Get battery charging voltage

let Batt_V =AD
PWM Chrg_Limit, Trickle_LVL, 1000

‘Turn on Trickle current

Low Chrg_Limit

‘Trickle to minimum current

Goto Main_Batt1

Chk_Pwr:
Let D1 = 1
Let D0 = 0
Gosub Convert
‘debug AD, Batt_V

‘Get battery charging voltage

if AD < Batt_V then No_ Power
return


No_Power:
‘debug “no_pwr”
pause 50
let Bat1_Chrg = 0

‘Indicate battery has been discharged

PWM Chrg_Limit, 0.50

‘turn off charge current

Goto Main_Batt1

Battery Charger Program

Batt_Chrg:
Let Chrg_Time = 0

‘Initialize charge timer (counts in sec.)

Chrg_Lp:
Gosub Chk_Pwr
For TCnt= 0 to 1
PWM Chrg_Limit,A01_LVL,1000

‘first apply charge current then

‘check for charge termination