Let DIOp =D0

‘next bit of command

Pulsout CLK.2

‘Activate the LTC1594

Low CS1

‘Get ready for input from LTC 1594

Input DIO


Pulsout CLK.2

‘Dummy statement for delay

Input DIO

‘Sampling requires two clocks

Pulsout CLK.2
Let AD = 0

‘Clear old ADC result.

For Adbits = 1 to 13

‘Get null bit + 12 data bits.

Pulsout CLK.2

‘Clock next data bit in.

Let AD = AD*2 +DIOp

‘Shift AD left, add new data bit.

Next Adbits

‘Get next data bit.

High CS1

‘Turn off the ADC

Return

‘Return to program.

‘D1 = 1, D0 = 0 channel 2 input, monitors input voltage of battery regulator
‘D1 = 1, D0 =1 channel 3 input, monitors battery charging current

‘Note: channel 0 is usually jumpered to CN3 term2 for monitoring battery voltage
‘Note: channel 2 tracks main power input when greater than battery voltage
‘Note: channel 2 approx. 0.6V less than battery voltage when main input less than battery
voltage.

SYMBOL AD = w1

12-bit ADC conversion result

SYMBOL Chrg Time = w2

16-bit timer

SYMBOL Batt_Peak = w3

Peak voltage detected

SYMBOL TCnt =b8

SYMBOL Batt_V = w5
SYMBOL sglDif = 1

Single-ended, two-channel mode.

SYMBOL msbf = 1

Output 0s after data transfer is complete.

SYMBOL AO1_LVL = 5

Maximum current level (50 = 1A 75 = 1.5A)

SYMBOL BattV_Max = 1100

Maximum battery pack charge voltage

SYMBOL Chrg_Time_Max =10800

Maximum battery charging time (10,800 = 3hr.)

SYMBOL Neg_DeltaV = 8

AD convertor points for –deltaV (74pt/V IE
0.2V=18pts).

SYMBOL Trickle_LVL = 0

Trickle Charge Level (12 =.25A) See below:

SYMBOL BattV_Min = 740

Minimum battery voltage (10V)



Main Loop

Init:

Low PSU_OnOff

‘Turn PSU on