TRF1500 Integrated Dual-Band RF Receiver User’s Guide

Low-Band Cascaded: RF Input Return Loss

Control state: 011000

The input return loss of the low band receiver is measured at the
EVM low band RF input port, J10. The measurement is
performed using a network analyzer.

Set up the network analyzer as follows to measure the RF input
return loss:

1) Set the network analyzer to measure the low band RF

frequency (see Table 3).

2) Set the power range to -35 dBm through -20 dBm, and then

set the input power to -30 dBm.

3) Perform a full one-port calibration on port 1 of the network

analyzer.

4) Set the network analyzer to measure S11.

5) Connect the EVM RF input, J10, to port 1 of the network

analyzer.

6) Measure the RF input return loss.

Low-Band Cascaded: LO Input Return Loss

Control state: 011000

The cascaded LO input return loss of the Low Band is measured
at the EVM low band LO input port, J12. The measurement is
performed using a network analyzer.

1) Set the network analyzer to measure the low band LO

frequency (see Table 3).

2) Set the power range to -35 dBm through -20 dBm, and then

set the input power to -30 dBm.

3) Perform a full one-port calibration on port 1 of the network

analyzer.

4) Set the network analyzer to measure S11.

5) Connect the EVM LO input port, J12, to port 1 of the network

analyzer.

6) Measure the LO input return loss.