Low band: lo buffer output power, Low-band: power leakage lo in to rf in – Texas Instruments TRF1500 User Manual

Page 30

Advertising
background image

SWRA004A

TRF1500 Integrated Dual-Band RF Receiver User’s Guide

31

LOW BAND: LO Buffer Output Power

Control state: 011000

SEE APPENDIX A: TEST BENCH SETUPS

Test setup Figure 20

This section involves measuring the Low Band LO Buffer Output.
All unused ports will be terminated into 50

. The LO buffer output

power is measured at the EVM low band LO output port J13. A
transformer balun is used to convert the differential output to a
single ended output. The measurement is performed using a RF
source and a spectrum analyzer.

1) Set the LO source frequency and input power (see Table 3).

Connect the LO source to the EVM LO input port, J12.

2) Set the spectrum analyzer to measure at the LO frequency

(see Table 3).

3) Connect the EVM LO buffer port, J13, to the spectrum

analyzer.

4) Measure the LO buffer output power.

Low-Band: Power Leakage LO In to RF In

Control state: 011000

SEE APPENDIX A: TEST BENCH SETUPS

Test setup Figure 23

The LO leakage at the RF port is measured at the low band RF
input port J10. Power leakage is a measure of power in dBm that
couples to the RF port. The measurement is performed using a
RF source and a spectrum analyzer.

1) Set the LO source frequency and input power (see Table 3).

Connect the LO source to the EVM LO input port, J12.

2) Set the spectrum analyzer to measure at the LO frequency

(see Table 3).

3) Connect the RF Port, J10, to the spectrum analyzer.

4) Measure the LO leakage power.

Advertising