FLOW or NFLOW – Flow sensor alarms

When flow monitoring is used, the FLOW

error message will be displayed when a

station experiences an over-, under-, or

critical-flow error. In this event, the station

is skipped, and the next programmed

station in sequence is operated.

Error message NFLOW is displayed if the

Nominal flow threshold (flow measured

while controller is idle) is exceeded. When

a Normally Open master valve is controlled

by the flow module, it will be activated

(valve closed).

To clear the warning, press any button.

The controller will continue to operate as

scheduled and will attempt to run all

stations as programmed.

SEN – Rain sensor active

When the rain sensor is active and all

controller outputs are off, the SEN prompt

is displayed. Rain sensor input can be

bypassed with the controller’s Sensor

Bypass switch, the Timed Bypass feature

and rain sensor receiver controls.

For complete information regarding rain

sensor operation, refer to the user’s guide

provided with the TWRS/TWRFS units.
PAUSE – Watering suspended by TMR-1

handheld remote.

When irrigation is paused with the handheld

remote, PAUSE will be displayed.
NOTE: When a display language option is

used, – x – will be shown.