Operation, Cable specifications, Continued product features – Transition Networks CETTF10XX-105 User Manual

Page 4: Fiber cable

Advertising
background image

CETTF10xx-105

6

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Operation

-- Continued

Product Features

AutoCross

When the AutoCross feature is activated, it allows either straight-through
(MDI) or crossover (MDI-X) copper cables to be used when connecting to
10Base-T devices. AutoCross determines the characteristics of the connection
and automatically configures the unit to link up, regardless if the copper cable
is MDI or MDI-X configuration.

NOTE: Factory default is “enable AutoCross.” Transition networks
recommends leaving the device in the “enable” mode.

Link Pass Through

The Link Pass-Through feature allows the media converter to monitor both the
fiber and copper RX (receive) ports for loss of signal. In the event of a loss of
an RX signal (1), the media converter will automatically disable the TX
(transmit) signal (2), thus, “passing through” the link loss (3). The far-end
device is automatically notified of the link loss (4), which prevents the loss of
valuable data unknowingly transmitted over an invalid link.

NOTE: An enable/disable switch allows the Link Pass Through feature to be
disabled. Link Pass Through may interfere with the Auto-Negotiation feature
of other devices in networks where there are two media converters installed in
series.

4

1

Media

Converter A

Media

Converter B

Near-End

Device

Far-End

Device

original fault

on the copper link

media converter B

disables the copper link

media converter A

disables the fiber TX link

3

2

media converter B

loses the fiber RX link

7

[email protected] -- Click the “Transition Now” link for a live Web chat.

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Fiber Cable

Bit Error Rate:

<10-9

Single mode fiber (recommended):

9 µm

Multimode fiber (recommended):

62.5/125 µm

Multimode fiber (optional):

100/140, 85/140, 50/125 µm

CETTF1011-105

850 nm multimode

CETTF1013-105

850 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

CETTF1012-105

1310 nm single mode

Fiber Optic Transmitter Power:

min: -27.0 dBm

max: -10.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -14.0 dBm

Link Budget:

7.0 dB

CETTF1014-105

1310 nm single mode

CETTF1014-106

1310 nm single mode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -3.0 dBm

Link Budget:

15.0 dB

CETTF1015-105

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber Optic Receiver Sensitivity:

min: -38.0 dBm

max: -8.0 dBm

Link Budget:

23.0 dB

CETTF1018-105

850 nm multimode

Fiber Optic Transmitter Power:

min: -16.0 dBm

max: -10.0 dBm

Fiber Optic Receiver Sensitivity:

min: -29.5 dBm

max: -7.2 dBm

Link Budget:

13.5 dB

CETTF1022-105

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -14.0 dBm

Link Budget:

19.0 dB

CETTF1027-105

1300 nm multimode

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -15.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

CETTF1029-105

1310 nm (TX) / 1550 nm (RX) simplex

CETTF1029-106

1550 nm (TX) / 1310 nm (RX) simplex

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -8.0 dBm

Fiber Optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

The fiber optic transmitters on this device meets Class I Laser safety
requirements per IEC-825/CDRH standards and complies with 21
CFR1040.10 and 21CFR1040.11.

Advertising