LAE Electronic Control

Info/Set Point

Button

Manual Defrost/

Down Button

Manual Activation/

Up Button

Stand-By

Button

HOW TO CHANGE THE “SET POINT”

WHY:
THE SET POINT IS THE TEMPERATURE AT WHICH THE

COMPRESSOR WILL SHUT OFF.
Please note that the “set point” IS NOT the cabinet

holding temperature.

HOW:
A.
To see the set point, press and hold the info button

and the stand-by button at the same time.

“ScL” will appear. See image 1.

B. Push the up button three times until “SP”

appears. See image 2.

C. Press and hold the info button to see the

“set point”. See image 3.

D. While pressing and holding the info button ,

press the up or down button to change

the “set point”.

E. Once the “set point” has been set correctly release the

info button .
Wait 30 seconds for the display to show temperature.

See image 4.

1

2

3

4

Compressor

Running

Activation of 2nd

Parameter Set - NA

Alarm - NA

Cabinet in Defrost

Evaporator Fan

Running

LAE Control Icons

May need to unlock control.

ALL OTHER SETTINGS ARE FACTORY PRE-SET AND SHOULD NOT BE CHANGED.

If you have any questions, please call TRUE technical service.

TRUE EUROPE • Fields End Road • Goldthorpe • NR, Rotherham • South Yorkshire UK • UK Office/Technical +44 (0) 1709 888 888

UK Free Phone 0800 783 2049 • UK Free Phone from France, Germany, Netherlands, Belgium & Republic of Ireland 00-880-8783-4685

TRUE FOOD INTERNATIONAL, INC. • 2001 East Terra Lane • O’Fallon • Missouri • 63366-4434 • USA

USA Office/Technical (001) 636-240-2400 • Email [email protected]

Advertising
This manual is related to the following products: