How to add a “defrost cycle, Lae electronic control, May need to unlock control – True Manufacturing Company TGU-2 User Manual
Page 18: True food international equipment, inc
............ www.truemfg.com ............
True Food International Equipment, Inc.
16
16
LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons
ALL OTHER SETTINGS ARE FACTORY PRE-SET AND SHOULD NOT BE CHANGED.
If you have any questions, please call TRUE technical service.
TRUE EUROPE • Fields End Road • Goldthorpe • NR, Rotherham • South Yorkshire UK • UK Office/Technical +44 (0) 1709 888 888
UK Free Phone 0800 783 2049 • UK Free Phone from France, Germany, Netherlands, Belgium & Republic of Ireland 00-880-8783-4685
TRUE FOOD INTERNATIONAL, INC. • 2001 East Terra Lane • O’Fallon • Missouri • 63366-4434 • USA
USA Office/Technical (001) 636-240-2400 • Email [email protected]
WHY:
THE DEFROST TIME IS THE TIME OF DAY DEFROST CYCLES ARE INITIATED.
Time of Day must be set ensure that factory set defrost times are
occur at the correct times. By adding a cycle you will be adding an
extra specific defrost start time. A manual defrost may be initiated by
pressing and holding the “manual defrost” button for 4 seconds.
After “dh1” appears, release and press again the “manual defrost”
button for an additional 4 seconds.
HOW:
A. To see the defrost times press and hold the info button and
the stand-by button at the same time.. “ScL” will appear.
See image 1.
B. Push the “up” button eleven times until “dh1” appears.
See image 2.
C. Press and hold the info button to see the “defrost time”.
See image 3.
Note: Clock times are displayed in 24 hour format ranging from 0-23.5.
D. Release and push the info button to scroll “dh1” - “dh6”
which show the factory pre-set defrost times. See image 4.
Additional time of day may be added when the time for defrost
shows “---”.
E. While pressing and holding the info button press the down
button to add “defrost time”. See image 5.
F. Once the “defrost time” has been added release the info button.
Wait 30 seconds for the display to show temperature. See image 6.
HOW TO ADD A “DEFROST CYCLE”
1
3
2
4
5
6
May need to unlock control.