Parameter

Type

Comments

verticalPosition
(optional)

String

Specifies where to show the message: “top”, “middle”
or “bottom”. Message is always horizontally
centered, and omitting this parameter is equivalent to
choosing “middle”.

durationSeconds
(optional)

Integer

The length of time, in seconds, to display the
message. This defaults to 30 seconds.

4.19 participant.diagnostics

Returns diagnostic information about a given participant.

Parameter

Type

Comments

conferenceName String
autoAttendantUniqueId String
participantName String
participantProtocol String
participantType String

Participant identification as described above.


The method response returns the following:

Response

Type

Comments

videoTxFrameRate Integer

videoRxFrameRate Integer

videoRxFramesReceived Integer

videoTxChannelBitRate Integer

videoTxSelectedBitRate Integer

videoTxActualBitRate Integer

videoTxLimitReason String

One

of:

notLimited

,

viewedSize

,

quality

,

aggregateBandwidth

,

flowControl

or

endpointLimitation

.

videoRxChannelBitRate Integer

videoRxSelectedBitRate Integer

videoRxActualBitRate Integer

videoRxLimitReason String

One

of:

notLimited

,

viewedSize

,

quality

,

aggregateBandwidth

,

flowControl

or

endpointLimitation

.

videoTxWidth Integer
videoTxHeight Integer
videoTxInterlaced Boolean

videoRxWidth Integer
videoRxHeight Integer
videoRxInterlaced Boolean

4.20 autoAttendant.enumerate

Parameter

Type

Comments

enumerateID(optional) String

The value returned by the last enumeration call, if
omitted, a new enumeration is started.


This function has no valid enumerate filter expressions.