Troubleshooting

Fault

Check

Action

No power to the
loudspeaker

Is the mains lead plugged in?

Connect the mains lead

Is the mains outlet live?

Check the mains outlet or switch to
another outlet

Is the power switch on?

Press the mains switch

No sound / quiet sound

Are the level controls turned
down (anti-clockwise)?

Turn the control slowly clockwise

Is the source sending a signal? Verify signal at the source output.

Un-mute muted outputs or mixer
channels. Check cables and replace

No sound from
connected microphone

Is the microphone a
condenser type needing
phantom power?

Milan does not supply +48v
phantom power. Use a dynamic
microphone or connect to a mixer
with phantom power

No sound although
loudspeaker is on

Is the loudspeaker in protect
mode?

Turn off the mains switch, unplug
the loudspeaker before
reconnecting

Does the loudspeaker remain
in protect mode?

Refer to qualified service personnel

Distorted sound

Is the input signal level too
high?
Is the mic/line switch set
incorrectly?

Reduce mixer or preamp level

Change mic/line setting to correct
source

Distorted sound, limit
LED is on continuously

Are the level controls set too
high?

Reduce volume controls or use
additional loudspeakers

Hum or noise

Are the connected sources
balanced?

Use balanced cables and 3-pole
connectors wherever possible.
Check wiring.

Ground loops?

Lift audio ground on affected
device with adapter

Are signal cables near or
running parallel to mains
cables?

Move signal cables

Advertising