Rssi / carrier sense, If section, Frequency synthesizer section – Texas Instruments 3138 155 232931 User Manual

Page 11: Cc2420

Advertising
background image

CC2420

SWRS041B Page 11 of 89

Parameter

Min.

Typ.

Max.

Unit

Condition / Note

Frequency error tolerance

-300

300

kHz

Difference between centre
frequency of the received RF
signal and local oscillator
frequency

[1] requires 200 kHz

Symbol rate error tolerance

120

ppm

Difference between incoming
symbol rate and the internally
generated symbol rate

[1] requires 80 ppm

Data latency

3

µs

Processing delay in receiver.
Time from complete transmission
of SFD until complete reception
of SFD, i.e. from SFD goes active
on transmitter until active on
receiver.

6.4

RSSI / Carrier Sense

Parameter

Min.

Typ.

Max.

Unit

Condition / Note

Carrier sense level

− 77

dBm

Programmable in
RSSI.CCA_THR

RSSI dynamic range

100

dB

The range is approximately from
–100 dBm to 0 dBm

RSSI accuracy

± 6

dB

See page 48 for details

RSSI linearity

± 3

dB

RSSI average time

128

µs

8 symbol periods, as specified by
[1]

6.5 IF

Section

Parameter

Min.

Typ.

Max.

Unit

Condition / Note

Intermediate frequency (IF)

2

MHz

6.6

Frequency Synthesizer Section

Parameter

Min.

Typ.

Max.

Unit

Condition / Note

Crystal oscillator frequency

16

MHz

See page 53 for details.

Crystal frequency accuracy
requirement

- 40

40

ppm

Including aging and temperature
dependency, as specified by [1]

Crystal operation

Parallel

C381 and C391 are loading
capacitors, see page 53