Operation

switch Modes

After configuring, mounting and connecting your Inverter/Charger,

you are able to operate it by switching between the following operat-

ing modes as appropriate to your situation:
“AUTO/REMOTE”: Switch to this mode when you

need constant, uninterrupted AC power for connected

appliances and equipment. The Inverter/Charger will

continue to supply AC power to connected equipment

and to charge your connected batteries while utility-

or generator-supplied AC power is present. Since the

inverter is ON (but in Standby) in this mode, it will automatically

switch to your battery system to supply AC power to connected

equipment in the absence of a utility/generator source or in over/

under voltage situations. “AUTO/REMOTE” also enables an option-

al remote control module (Tripp Lite model APSRM4, sold sepa-

rately) to function when connected to the unit.
“CHARGE ONLY”: Switch to this mode when you

are not using connected appliances and equipment in

order to conserve battery power by disabling the

inverter. The Inverter/Charger will continue to sup-

ply AC power to connected equipment and charge

connected batteries while utility- or generator-sup-

plied AC power is present. However, since the inverter is OFF in this

mode, it WILL NOT supply AC power to connected equipment in

the absence of a utility/generator source or in over/under voltage

situations.
“DC OFF”: Switch to this mode to prevent the

inverter from drawing power from the batteries. Use

this switch to automatically reset the unit if it shuts

down due to overload or overheating. First remove

the excessive load or allow the unit to sufficiently

cool (applicable to your situation). Switch to "DC OFF", then back

to "AUTO/REMOTE" or "CHARGE ONLY" as desired. If unit fails

to reset, remove more load or allow unit to cool further and retry.

Use an optional remote control module (Tripp Lite model APSRM4,

sold separately) to reset unit due to overload and overtemperature.
CAUTION: The unit will always pass AC power through to con-

nected equipment if plugged into a live AC outlet, regardless of

the position of the Operating Mode Switch.

Indicator Lights

Your Inverter/Charger is equipped with a simple, intuitive, user-

friendly set of indicator lights. These easily-remembered “traffic

light” signals will allow you, shortly after first use, to tell at a glance

a wide variety of operating details.
“LINE Green LED”: If the operating mode switch is set to “AUTO/

REMOTE”, this light will ILLUMINATE

CONTINUOUSLY when your connected equipment

is receiving continuous AC power supplied from a

utility/generator source.
If the operating mode switch is set to “CHARGE

ONLY”, this light will BLINK to alert you that the

unit’s inverter is OFF and will NOT supply AC power in the absence

of a utility/generator source or in over/under voltage situations.

Indicator Lights

(Continued)

“INV” (Inverting) Yellow LED: This light will

ILLUMINATE CONTINUOUSLY whenever con-

nected equipment is receiving battery-supplied,

inverted AC power (in the absence of a utility/genera-

tor source or in over/under voltage situations). This

light will be off when AC power is supplying the

load.
“LOAD” Red LED: This red light will ILLUMINATE

CONTINUOUSLY whenever the inverter is func-

tioning and the power demanded by connected appli-

ances and equipment exceeds 100% of load capacity.

The light will BLINK to alert you when the inverter

shuts down due to a severe overload or overheating.

If this happens, turn the operating mode switch to “DC OFF”;

remove the overload and let the unit cool. You may then turn the

operating mode switch to either “AUTO/REMOTE” or “CHARGE

ONLY” after it has adequately cooled. This light will be off when

AC power is supplying the load.
"BATT VOLTAGE" LEDs: If the operating mode switch is in the

"AUTO/REMOTE" or "CHARGE ONLY" position, the LEDs indi-

cate the approximate charge level and voltage of your connected

battery bank and alert you to several fault conditions. See Chart for

charge and voltage levels.

LED Function with Switch in "AUTO/REMOTE" or “Charge

Only” Position
Approximate Battery Charge Level*

LEDs

Battery Capacity

Illuminated

(Charging/Discharging)

Green

91%–Full

Green & Yellow

81%–90%

Yellow

61%–80%

Yellow & Red

41%–60%

Red

21%–40%

All three lights off

1%–20%

Flashing red

0% (Inverter

shutdown)**

* Charge levels listed are approximate. Actual conditions vary depending on battery condition
and load. ** Inverter shutdown protects battery against damage due to excessive discharge.

Fault Condition

LEDs

Fault

Illuminated

Condition

All three lights

Excessive discharge

flash slowly*

(Inverter shutdown)

All three lights

Overcharge (Charger

flash quickly**

shutdown)

*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown
protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼
second off. Charger shutdown protects battery against damage due to overcharge. May also
indicate a battery charger fault exists. See Troubleshooting section.