Toshiba 18 - 1250 A User Manual

Page 40

Advertising
background image

TE Series

Digital Solid State Soft Starters 18 – 1250A

33

5.5.9 Lockouts, Reset and Internal Protection Functions

5.5.10 Output Relay Programming Features

NOTE:
Check wiring to each relay before changing programming to ensure
there are no unintended consequences.
Relays programmed to some protection features will not operate if
function is disabled elsewhere.

Fn # Group

Function Description

Adjustment / Display Range

Setting

Increments

Factory

Setting

Section

F048

Lock

out

s, Rese

t and

Int

e

rnal Pr

otec

tion

Coast Down (Back Spin)
Lockout Timer

0 = Disabled, or 1 - 60 minutes

1 minute

0

Disabled

5.6.9

F049

Maximum Starts per Hour

0 = Disabled, or 1 – 10 starts

1

0

Disabled

F050

Minimum Time Between
Starts

0 = Disabled, or 1 - 60 minutes

1 minute

0

Disabled

F051

Internal Protection Settings

1 – 127
See“ F051 Definition Table”

1

127

Enable all

5.6.9.a

F052

Auto Reset
on Selected Faults

Fault Preferences 1 – 12
See Table 5.6.8:
”Auto-Reset Selected Faults”

1

4,

Phase

Loss only

5.6.9.b

F053

Auto Reset Attempts

0 = Disabled, or 1-10 attempts

1

1

F054

Restart Delay Time Value
Readout (for F028)

0-999 Minutes

1

0

5.6.9.c

F055

Coast Down Timer Value
for F048

1-3600 Seconds

1

0

F056

Starts Per Hour Timer Value
for F049

1-3600 Seconds

1

0

F057

Starts Per Hour
For F049

1-10 Starts

1

0

F058

Time Value Between Starts
for F050

1-3600 Seconds

1

0

F059

Thermal Capacity to Start
for F005

0-100 % Thermal Capacity

1

0

Table 5.5.9: Lockouts, Reset and Internal Protection Group

Fn # Group

Function Description

Adjustment / Display Range

Setting

Increments

Factory

Setting

Section

F060

Ou

tpu

t Rel

ays

Aux Relay 1 setting

Operation # 1 – 26: see
”Aux. Relay Settings Chart”

1 1

5.6.10

F061

Aux Relay 2 setting

Operation # 1 – 26: see
”Aux. Relay Settings Chart”

1 2

F062

Aux Relay 3 setting

Operation # 1 – 26: see
”Aux. Relay Settings Chart”

1 16

F063

Aux. Relay Delay Timer
(for Operations 23-26)

0 (Disabled), or 1-999 seconds

1 second

0

No Delay

F064

Reserved for factory use

Table 5.5.10: Output Relay Function Group

Advertising