Operation

Operation

Turning On The Scanner and

Setting Squelch

Note: Make sure the scanner's antenna is

connected before you turn it on.

1. Turn Squelch fully counterclockwise.

2. Press and hold

for about 2 seconds to turn

the scanner on, then turn Volume clockwise until
you hear a hissing sound.

3. If the scanner is scanning, press Hold to stop

scanning, then turn Squelch clockwise until the
hissing stops.

Storing Known Frequencies

Into Channels

1. Press Hold. Then enter the channel number

where you want to store a frequency, then press
Func and Pgm. The channel number appears.

2. Use the number keys and to enter the

frequency (including the decimal point) you want
to store.

3. Press E to store the frequency into the channel.
Notes:

If you entered an invalid frequency in Step 2,
Error appears and the scanner beeps three

times. Enter a valid frequency.

The scanner automatically rounds the entered
number to the nearest valid frequency.

For example, if you enter 151.473 (MHz), your

scanner accepts it as 151.475.

When you enter a frequency into a channel, the
scanner automatically turns on the delay

function and DLY appears. When delay is turned

on, the scanner automatically pauses scanning

Operation