MPEG-2 Configuration

VBrick MPEG-2 Appliance Admin Guide

39

Passthrough State: Responder

Passthrough State

Used to enable/disable Passthrough. Three states are possible:

• Disabled – The VBrick will neither initiate nor respond to

Passthrough setup requests.

• Responder – In this case the VBrick will accept a connection

request (up to 64 connection requests) from another VBrick set as
an Initiator or from a PC camera control application.

• Initiator – In this case it will continuously attempt to automatically

initiate a Passthrough connection to the remote destination.

Operational State

Describes the current status of a Passthrough connection, including
error conditions, if any. Refer to the Network Status Section. This will
display "Active" if in Passthrough mode.

COM Interface
Type

Describes the COM interface connector. (RS422/485 options are
displayed only if main board has a Part Number ending in xxx3. See
Status: User Information > Main Board.)

• RS232 – standard RS-232 serial port connector.
• RS422/485 – RS-422/485 4-wire serial port connector.
• RS422/485 (Terminated) – RS-422/485 terminated.