WIRING FOR TIELINE CONNECTION OF THE EXCHANGES

Each exchange can be connected by means of a cable with a diameter
of 0.65mm for a distance of up to 2km.

Regarding the tieline links which are not used, turn off the
DIP switch of each unused tieline link inside the Tieline Unit TI-52.

Connect "T" line (2 wires) of the 4 wires of each link to "R" line

(2 wires) of the other exchange.

The 2 wires of the "T" line and

"R" line have no polarity.

If the BOX-064 is used, its terminals No. 1 and 2 are for the

"R" line and No. 3 and 4 are for the "T" line.

1. Wiring for tieline connection of 2 exchanges

Exchange B

EX-2B

Exchange

A

EX-2A

Tie line unit TI-52

Tie line unit TI-52

Note 1. Any combination of tieline links between exchanges "A" and

"B" is possible. But, in consideration of possible increase

in the number of exchanges to be connected from 2 to 3 in the

future, we suggest you connect TL (link No. 0, 1, 2, 3) of
exchange "A" to TH (link No. 4, 5, 6, 7) of exchange "B".