Vizio CPU-56 User Manual

Page 6

Advertising
background image

FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS

(When the Exchanges are connected by means of Tie-line.)

Those functions of the CPU-56 which require either the addition of specific units or processing in existing units are as

mentioned below. Before installation and adjustment of equipment, make sure to check your system.

(For Data Transmitting and Receiving units, refer to Part 2. "Function Selection for Data Transmitting and Receiving

units" Page 43.)

CPU - 56
OCU - 52A

HCU - 52

SGD - 52A

DLU - 52

LMU - 52A

TI - 52

PIU-52/52A

AC POWER INDICATOR LAMP

BATTERY POWER INDICATOR LAMP
BUZZER STOP SWITCH

DS-550A

Function

Talk-Back from
paging speaker

Conference

External PA Paging

Station Paging

Tieline connection

of exchanges

Data Transmitting

and Receiving Units
DT-E11 and DR-B61

Additional Equipment

Required

Talk-Back Unit

Conference Unit

Paging Interface Unit

Paging Interface Unit

Tieline Unit

Output Unit

Frame

Frame

Unit Model

Nos.

TKU-11

CLU-52

PIU-52/52A

PIU-52/52A

TI-52

OCU-52A

FR-510A/B

520A/B

FR-510B

520B

Remarks

Optional amplifier (10W

max.) may be re-

quired depending on application

External PA Equipment is required.

1. Wiring of "Station Paging Assignment

Plug" located at the back of the frame of

the Exchange.

2. Cutting of LMU jumper wire to split sta-

tion paging system. (Refer to Service

Manual for LMU-52/52A, PIU-52/52A).

Turn off the DIP switch for tieline

links not used when the exchanges are
connected by tielines

OCU-52 must be modified.

(Add M9, M17 and TTL IC 7475 2 pcs.)

PIU-52A and TI-52 can be mounted.

with terminal for interface output

– 5 –