PART 2. FUNCTION SELECTION FOR DATA TRANSMITTING AND

RECEIVING UNITS

8. SETTING CHANNEL SELECT SWITCHES OF TRANSMITTING UNITS (DT-E11) AND WORD

SELECT SWITCH OF RECEIVING UNITS (DR-B61)

NOTE

1. Connect the DT-E11 and DR-B61 to Exchange cor-

rectly. (Refer to installation manuals of DT-E11 and

DR-B61.)

2. Set the function select switches (DIP SWITCH) on

CPU-55 correctly and be sure to enter initial pro-

gramming and function registration at programming

station No. 200.

3. Remove the front panel of Data Transmitting Unit

(DT-E11) and take out the printed circuit board. Then

set the channel select switches located on the printed

circuit board, according to the necessary functions

such as IN/OUT Annunciation, Calling Party Indication

etc, and replace in the Unit.

(Refer to 12. Explanation of Data Transmitting Unit

Output Channels, Page 39).

4. The DT-E11 sends out 512 bit data (16 bit x 32 words)

to control relays on Data Receiving Unit (DR-B61).

Therefore set the two word select switches on DR-B61,

according to necessary output mode. SW-1 is for

Relay No.1 to No.16 and SW-2 is for Relay No.17 to

No. 32. See Page 41 for details.

(Refer to Explanation of Data Receiving Unit Output

Channels.)

Relay Number

Connecting

Cable YR-802

Connecting

Cable

YR-803

To other DR-B61

To other

DT-E11

CHANNEL SELECT

Switch (SW-1)

To other DR-B61

WORD SELECT

Switch

(SW-1, SW-2)