6500plus integral dsu, Integral dsu – Vanguard Managed Solutions Vanguard 6500 PLUS User Manual

Page 25

Advertising
background image

About the 6500

PLUS

1-17

Hardware

6500

PLUS

Integral DSU

Introduction

The 6500

PLUS

Integral DSU option is intended for use in installations

requiring connection to a DDS interface, conforming to AT&T 62310 or ANSI
T1E1.4/91-006, and running at a rate of 56 kbps. At present, this optional DSU
interface is only available with VanguardMS 6500

PLUS

enclosures using a 25-pin D

connector interface.

The DSU option normally uses clocking derived from the network interface, but may
also be configured to originate the clocking, thus providing the standard DSU and
CSU loopbacks. Installation of the DSU option requires a hardware and software
upgrade to the base 6500

PLUS

product.

Hardware
Components

The DSU option consists of two hardware modules, the Data Interface Module
(DIM) and the External Interface Module (EIM).

DIM

The DSU DIM is a small (approximately 1 in. x 3.5 in.) circuit card installed as a
daughtercard onto the 6500

PLUS

processor card. The DIM module provides the

proper power to the EIM and also performs the data translation functions.

EIM

The EIM, shown in Figure 1-7, contains the telco interface circuitry portion of the
option.The EIM has an 18 in. cable with a 25-pin connection for interface with the
6500

PLUS

unit, and an RJ-48S jack for connection to the DDS line.

Example of an EIM

Figure 1-7 shows the EIM.

Figure 1-7. External Interface Module (EIM)

DSU Interface

The DIM and EIM modules work cooperatively to provide a DSU interface and must
be installed together for proper operation. These devices are only intended for use
with VanguardMS 6500

PLUS

equipment.

DB25 Connector

18-inch Cable

RJ-48S Jack

Advertising