2-40

Installation

Installing Nodes in Modulus Enclosures

Modulus 9/21 Nests The TRIM card has its own backplane and attaches to the solder side of the 6500

PLUS

processor card. The TRIM card requires two Modulus slots. The TRIM filler panel
for Modulus 9/21 nests is one slot wide as shown in Figure 2-10.

Figure 2-10. TRIM Card Rear Filler Panel for Modulus 9/21 Enclosures

Guidelines for
Installing a TRIM
Card in a Modulus
9/21 Enclosure

Consider the following if you install a TRIM card in a Modulus 9/21 enclosure:

Note

Before you add a TRIM card to an existing node, be sure the enclosure has room
for it as described above. To make space, you may need to rearrange cards and
backplanes, which requires a node shutdown first.

• A processor card with attached TRIM card requires four slots — two slots

each for the TRIM card and the processor card.

• The TRIM card attaches only to the processor card in the lowest-numbered

slot of a backplane (this is the master processor in a multi-processor node).

• When installing in a Modulus 21, install a horizontal bar on the front door to

meet FCC requirements.

TRIM Card
Filler Panel for
Modulus 9/21

65xx

18-Port

Backplane

Shielded
Twisted Pair

Unshielded
Twisted Pair

Modulus 9 Rear View

TRIM Card
Filler Panel for
Modulus 8/18

Use flat-head

screwdriver to

attach captive

hardware.