Vivotek FD7131 User Manual

Page 88

Advertising
background image




- 87 -


www.vivotek.com

T:

886-2-82455282

F:

886-2-82455532

trigger boot,

di,
motion,
seq,

6/6

Indicate the trigger condition.
“boot” indicates system boot.
“di” indicates digital input.
“motion” indicates video motion
detection.
“seq” indicates periodic condition.

di

<integer> 6/6

Indicate which di detected.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.

mdwin <integer>

6/6

Indicate

which motion detection

windows detected.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1

st

window.

For example, to detect the 1

st

and 3

rd

windows, set mdwin as 5.

inter

1~999

6/6

Interval of period snapshot in minute.
This field is used when trigger
condition is “seq”.

weekday

<interger> 6/6

Indicate which weekday is scheduled.
One bit represents one weekday.
The bit0 (LSB) indicates Saturday.
The bit1 indicates Friday.
The bit2 indicates Thursday.
The bit3 indicates Wednesday.
The bit4 indicates Tuesday.
The bit5 indicates Monday.
The bit6 indicates Sunday.
For example, to detect events on
Friday and Sunday, set weekday as 66.