ETV Portal Server Admin Guide

57

Synchronizing the Portal Server and the NVR

The internal clocks on the Portal Server and the NVR must be synchronized for recording
functionality to work properly. You can use the

Net time

command as explained below or you

can use an external time server. In order to run the

Net time

command on either server, the

server must be on the domain, and the user logged onto the server must have admin
privileges and be part of the domain. To synchronize the Portal Server and the NVR use the
following command:

Windows 2003 Server – Open a command prompt on the Portal Server and type:

Net time \\{NVR IP Address} /SET

Script Devices

Script devices work with scripts and can be used to control VBricks, or other devices
attached to a VBrick via the serial port. In order to use a script, the device (a VBrick, IP
Receiver, camera, VCR, etc.) must be defined in the Portal Server database as a script device.
Once defined, they can be subsequently controlled by a script (see Scripts on page 59)
launched from the Portal Server Scheduler. A script device must be physically connected to
the network and must be available at the runtime of a scheduled event. For example, PTZ
cameras respond to pan, tilt, and zoom commands. Once defined as a script device, pan,
zoom, and tilt commands can be scripted and executed from ETV Portal Server to control
the movement of the camera at a specific date, time, and recurrence.

Record Path

Path and folder where all recording are stored. By default, recordings
are stored on the D: drive. If you install ETV Portal Server on a
system without a D: drive, you must change the path. Also, in order to
record multiple streams, the Record Path must be under FTP root. For
example, if root is

C:\Inetpub\ftproot

the Record Path must be

C:\Inetpub\ftproot\<your_folder>

Max. Recording

The default number of concurrent recording sessions allowed is 2. If
you exceed 2, you must purchase a Network Video Recorder. Without
an NVR, any attempt to record more than 2 concurrent sessions will
fail.

FTP User Name

FTP user name in operating system of Recorder server.

FTP Password

FTP password in operating system of Recorder server.

Confirm Password FTP password in operating system of Recorder server.

Domain Name

This field is required only if the Recorder server is not on the local network.
Enter the domain name if the Record Path above points to a server in
a different domain,

User Name

The user name who has access to the specified path.

User Password

The corresponding password for this user name.

Note You can also write a script (launched from the Portal Server) that uses TCP/IP to

communicate with any compatible device on the network. Contact VBrick Support
Services for
more information.