Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you

must meet minimum clearance between mantel

shelf and top of fireplace opening.

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NOTICE: If your installation does

not meet the minimum clear-

ances shown in Figure 11, you

must do one of the following:

• raise the mantel to an accept-

able height

• remove the mantel

INSTALLATION

Continued

OPTIONAL MANTEL INSTALLATION

Refer to instructions provided with the mantel

for assembly instructions. Refer to the follow-

ing instructions for system installation. Refer to

instructions on page 6 for hood assembly. Blower

accessory should be installed prior to mantel if

it is being used (see Installing Optional Blower

Accessory GA3450TA, page 13).
1. Assemble cabinet mantel as shown in acces-

sory instruction sheet.

2. If blower is installed, install a properly

grounded, 120 volt three-prong electrical out-

let at fireplace location if an outlet is not there.

If possible, locate outlet so cabinet mantel will

cover it when installed (see Figure 12).

3. Place hearth base against wall at installation

location. Cut an access hole in hearth base to

run gas line to fireplace (see Figure 12). Make

sure to locate access hole so cabinet mantel will

cover it when installed. Note: You can secure

base to floor using wood screws. Countersink

screw heads and putty over.

4. Route flexible gas line through access hole in

hearth base.

5. Center cabinet mantel on hearth base (see Figure

13, page 13). Make sure mantel is flush against

wall and centered left to right on base.

6. Use screws provided with mantel accessory

to attach mantel assembly to base (see mantel

instruction sheet).

7. Attach flexible gas line to fireplace gas regula-

tor. See Connecting to Gas Supply, page 16.

8. Route electrical cord(s) through access holes

in either side of fireplace with bushing. Plug

electrical cord(s) into electrical outlet.

9. Check all gas connections for leaks. See

Checking Gas Connections, page 18.

10. Carefully insert fireplace into cabinet mantel (see

Figure 13, page 13). Be careful not to scratch or

damage hearth base or cabinet mantel.

13"

16"

19"

21"

2

1

/

2

"

6"

8"

10"

Note:
All vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.

Figure 11 - Minimum Mantel Clearances

for Built-In Installation

Mantel Shelf

Side of
Firebox

Figure 12 - Placing Hearth Base Against Wall

Hearth
Base

Electrical
Outlet

Pipe and Gas
Shutoff Valve