Inspecting burner, Operating fireplace – Vanguard Heating VMH26TPC User Manual

Page 21

Advertising
background image

www.desatech.com

113111-01D

21

OPERATING FIREPLACE

Continued

OPERATING

BLOWER

This blower has three settings: ON, OFF, and

AUTO. In the ON position, the blower will oper-

ate constantly. In the OFF position, the blower

will not operate. In the AUTO position, the

blower will start when the thermostat senses a

sufficient increase in firebox temperature.
Note:

Your fireplace and thermostat blower

will not turn on and off at the same time. The

fireplace may run for several minutes before the

blower turns on. After the heater modulates to

the pilot position, the blower will continue to

run. The blower will shut off after the firebox

temperature decreases.
Note:

It is safe to operate fireplace with blower

turned off. However, the blower helps distribute

heated air from the fireplace.

OF

F

ON

Auto/Off/On
Switch

Figure 30 - Auto/Off/On Switch

INSPECTING BURNER

Check pilot flame pattern and burner flame pat-

tern often.

PILOT FLAME PATTERN

Figure 32 shows a correct pilot flame pattern.

Figure 33 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not properly heating the

thermocouple. This will cause the thermocouple to

cool. When the thermocouple cools, the fireplace

will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 33
• turn fireplace off (see To Turn Off Gas to Ap-

pliance, page 20)

• see Troubleshooting, page 23
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

have no yellow or orange color.

Thermocouple

Pilot Burner

Figure 31 - Correct Pilot Flame Pattern

(Propane/LP Shown)

Thermocouple

Pilot Burner

Figure 32 - Incorrect Pilot Flame Pattern

(Propane/LP Shown)

BURNER FLAME PATTERN

Figure 33 shows a correct burner flame pattern.

Figure 34 shows an incorrect burner flame pattern.

The incorrect burner flame pattern shows sporadic,

irregular flame tipping. The flame should not be

dark or have an orange/reddish tinge.
Note:

When using the fireplace the first time, the

flame will be orange for approximately one hour

until the log cures.
If burner flame pattern is incorrect, as shown in

Figure 34
• turn fireplace off (see To Turn Off Gas to Ap-

pliance

, page 20)

• see Troubleshooting, page 23

Figure 33 - Correct Burner Flame Pattern

Figure 34 - Incorrect Burner Flame

Pattern

Advertising
This manual is related to the following products: