Vinotemp VINO1500HZD User Manual

Page 15

Advertising
background image

- 14 -

2. The value of the set point will be displayed and the “°C” or “°F” LED starts
blinking;
3. To change the Set value, push the keys

or

arrows within 10s.

4. To memorize the new set point value, push the SET key again or wait 10s.

4) Humidity Adjustment

The parameter Fon is used to adjust the humidity in the wine cabinet. The higher
value of Fon, the higher relative humidity will be.

1. Press the Set +

keys for 3 sec until the “°C” or “°F” LED starts blinking.

2. Release the keys, then push again the Set +

keys for more than 7sec, the

Pr2 label will be displayed.
3. Release the keys, select the required parameter Fon by up or down keys

.

4. Press the “SET” key to display its value.
5. Use up or down keys

to change its value.

6. The default value is 0, change high or low value to maintain high or low
humidity.
7. Press “SET” to store the new value.
8. To exit: Press SET +

or wait 15sec without pressing a key.

5) Regulation Differential

The parameter Hy is used as intervention differential for set point. Compressor
cut-in is the set-point + Hy, and compressor cut-out is the set-point.

1. Press the Set +

keys for 3 sec until the “°C” or “°F” LED starts blinking.

2. Release the keys, then push again the Set +

keys for more than 7sec, the

Pr2 label will be displayed.
3. Release the keys, HY will display immediately.
4. Press the “SET” key to display its value.
5. Use up or down keys

to change its value.

6. The default value is 4, change high or low value to result in long high or short
running cycle.
7. Press “SET” to store the new value.
8. To exit: Press SET +

or wait 15sec without pressing a key.

6) Defrost Cycle

The parameter IdF is used as interval between defrost cycles.

1. Press the Set +

keys for 3 sec until the “°C” or “°F” LED starts blinking.

2. Release the keys, then push again the Set +

keys for more than 7sec, the

Pr2 label will be displayed.
3. Release the keys, select the required parameter IdF by up or down keys

.

4. Press the “SET” key to display its value.
5. Use up or down keys

to change its value.

6. The default value is 24, change high or low value to result in less or more
defrost cycle.
7. Press “SET” to store the new value.
8. To exit: Press SET +

or wait 15sec without pressing a key.