f.

Refrigerant low or leaking


g. Capillary tube blockage

f. Check for current and sealed

system leakage

g. Check for low side pressure

11.Water leak

a. High humidity
b. Air leak in wine cellar
c. Evaporator air flow restriction

d. Water passages restricted
e. Drip tray leak

a. Use drain line
b. Check for any air leak
c. Check air flow or air TD crossing

evaporator

d. Clean the drip tray
e. No water overflow but leak

12.Circuit

tripping

a. Incorrect fuse or breaker
b. Incorrect

wirings

c. Failed

components

a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service

13.Noisy

operation

a. Mounting area not firm
b. Loose

parts



c. Compressor overloaded due to

high ambient temperatures or
airflow restriction

d. Malfunctioning

components

a. Add support to improve installation
b. Check fan blades, bearings, cabinet

washers, tubing contact and loose
screws.

c. Check for airflow blockage


d. Call service for checking internal

loose, inadequate lubrication and
incorrect wirings