6. “HA” alarm

blinking and
beeping,
temperature
high or not
cooling and
running
continually

a. Improper room insulation & seal

b. Room too large
c. Ambient temperature too high
d. Exhaust restricted



e. Malfunctioning

fans


f.

Improper evaporator or
condenser airflow

g. Dirty

Condenser

h. Iced

evaporator

i. Refrigeration

system

restriction


j. Refrigerant

leak


k. Undercharge or overcharge

l. Failed

components

a. Check for insulation, gasket and

door opening

b. Check for excessive size
c. Check for installation location
d. Leave minimum 3 feet clearance for

the exhaust side and leave
minimum 1 foot clearance for the
fresh air intake side

e. Check for both evaporator and

condenser fans

f.

Check for air restrictions


g. Clean

condenser

h. Defrost and reset temperature
i.

Call service for checking
restrictions

j. Call service for checking loss of

refrigerant

k. Call service to add or remove

refrigerant

l. Check compressor windings, start

relay and overload protector

7.Unit running

too long

a. Improper room insulation & seal

b. Exhaust restricted



c. Room too large

d. Ambient temperature higher >

90

°

F

e. Dirty Condenser

a. Check for insulation, gasket and

door opening

b. Leave minimum 3 feet clearance for

the exhaust side and leave minimum
1 foot clearance for the fresh air
intake side

c. Check for excessive size or increase

setting

d. Check for installation location or

increase setting

e. Clean condenser

8.Fan motor

running but
compressor
not running

a. Post-compressor fan running

mode

b. Incorrect power supply
c. Incorrect or loose wirings
d. Failed

components


e.

Liquid refrigerant in the
compressor

a. Check for fan running time FON

b. Check for proper voltage
c. Check all wirings and connections
d. Check start relay, start capacitor,

overload protector, compressor.

e. Call service for OEM information.

9.Compressor

running but
fan not
running

a. Fan blade stuck
b. Incorrect or loose wirings
c. Failed

motors

a. Check for proper clearance
b. Check all wirings
c. Call service for checking open or

shorted windings

10.Evaporator

Icing

a. Evaporator air flow restriction
b. Not stopping due to air leak, high

ambient temperature or low
setting

c. Low ambient temperature
d. Bad thermostat or sensor
e. Moisture in the system

a. Check for fans
b. Check for seal, door opening,

ambient temperature and setting


c. Defrost

unit

d. Check for thermostat and sensor
e. Working initially then stopping