Vector IVECO MOTOS V08 ENT M12 User Manual

Page 35

Advertising
background image

INSTALLATION DIRECTIVE

MAY 2006



V08 EnT M75 - M11 - M12

Clogged air filter sensor

Vacuum switch, providing the signal for the clogged air filter

alarm indicator.

Operating voltage:

from 6 to 24 V

Condition at ambient pressure

normally open

Closing vacuum:

≥ -52 mbar

Operating temperature:

-20 / +80 °C

Maximum current

0.1 A (not inductive)

Electrical poles

isolated

Clogged oil filter sensor

Differential pressure switch, providing the signal for the

related indicator when pressure difference between inlet /

outlet oil filter is more then a limit value.

Operating voltage:

from 6 to 24 V

Condition at ambient pressure

normally open

Closing pressure:

2.4 ± 0.3 bar

Opening pressure:

1.8 ± 0.3 bar

Maximum current

3 A (not inductive)

Electrical poles

isolated

Figure 0

Figure 1

Clogged fuel filter sensor

Figure 2

Pressure switch, providing the signal for the related indicator,

when the pressure at the fuel filter inlet is too high.

Operating voltage:

from 6 to 24 V

Condition at ambient pressure

normally closed

Opening pressure:

1.5 ± 0.1 bar

Maximum current

0.1 A (not inductive)

Electrical poles

isolated

Exhaust gas temperature sensor

niCr-ni thermocouple sensor with insulated poles, pro-

viding the signal for the analog indication of exhaust gas

temperature.

Temperature

Voltage

°C

mV

100

4.10

200

8.13

300

12.21

400

16.40

500

20.65

600

24.91

700

29.14

800

33.30

900

37.36

Figure 

04_029_C

04_030_C

04_260_n

04_238_n

Advertising