INSTALLATION DIRECTIVE

MAY 2006

6

V08 EnT M75 - M11 - M12

CAUTION

In order to enable the proper working of the sensor to

detect water in fuel, the pre-filter support needs to be

electrically connected to the negative battery terminal.

In the engine models which use parts with insulated poles

it is necessary to electrically insulate the prefilter support

from the boat mass and then connect the support with the

negative battery terminal.

Neutral gear sensor

CAUTION

When neutral gear sensor is installed remember to con-

nect it to GN connector.

In installation without sensor, do not remove the cap of

the GN connector to avoid compromising start engine

function.

Sensor to detect water in fuel

Fuel resistivity sensor, integrated with the control and ampli-

fication electronic circuit, providing the signal for the indica-

torof the presence of water in the fuel.

Operating voltage

from 12 to 24 V

Condition in the absence of water open circuit
Closed condition

resistance of the liquid

≤ 1 MΩ

Operating temperature

from -20 to +80 °C

Connections of the sensor detecting the presence of water
in fuel

1. M Connector of the engine wire harness -

2. Sensor detecting the presence of water in the fuel -

3.Wiring harness (outfitter’s responsibility).

The three pole connection between the sensor for detect-

ing the presence of water in the fuel and the engine wire

harness must be produced by the outfitter according to the

position of the fuel prefilter in the boat.

Connection to the engine wire harness requires a METRI-

PACK150 three-pole connector with three male terminals;

connection to the sensor requires a JUnIOR TIMER three-

pole connector with three female terminals.