background image

- 11 -

3. WM-3500~8500HZD through-wall installation

Fig. 2.8 THROUGH- WALL INSTALLATION

• The cooling unit shall be mounted near the ceiling with equal distance from

each side of the room.

• Cut a rectangular opening at the wine room wall as illustrated. The

dimensions of the opening shall be 1/4” larger than the width and height of the
cooling unit.

• If top exhaust installation, cut another rectangular opening at the top of the

room to the length and width of the top exhaust.

• Construct a shelf as shown. The shelf must be capable of supporting the

weight of the cooling unit and preventing it from moving.

• Place the cooling unit on the shelf with the back of the unit flush with the

outside of the wall.

• Seal the clearance between the cooling unit and opening with a high quality

weather stripping, polyurethane spray foam, or foam tape. Cover the seal with
molding and attach the molding to the wall not the unit.

• If top exhaust installation, place another gaskets along the top exhaust at the

top of the cooling unit.

• Install a wall grille on the room exterior wall.

• Plug the unit into a properly grounded and dedicated outlet of adequate

capacity.

Advertising