Vinotemp WINE-MATE VINO2500HZD User Manual

Page 22

Advertising
background image

- 21 -

low

b. Low ambient temperature
c. Air probe fault
d. Temperature controller fault

b. Move to another location
c. Change a new one
d. Change a new one

13.Evaporator

freezing up

a. Evaporator air flow restriction
b. Condenser air flow restriction
c. Not stopping due to air leak, high

ambient temperature, low
temperature setting or pull-down
cooling

d. Defective controller or probe
e. Low ambient temperature
f. Initially working then stopping,

moisture in the system

g. Refrigerant low or leaking
h. Capillary tube or expansion valve

blockage

a. Check for fans and CFM
b. Check for fans and CFM
c. Check for seal, door opening,

ambient temperature and
temperature setting


d. Check for controller and probe
e. Change defrost cycle
f. Call

service


g. Call service
h. Call service

14.Water leak

a. Air leak in the wine cellar

(excessive condensate on the
front of the cooling unit)

b. High humidity
c. Evaporator air flow restriction or

low refrigerant

d. Water passages restricted
e. Drip tray leak (No water overflow

but water leak)

a. Check for any air leak


b. Use drain line
c. Check supply air flow or air TD

crossing evaporator

d. Clean the drip tray
e. Seal the leak using silicone sealant

15.Circuit

tripping

a. Incorrect fuse or breaker
b. Incorrect

wirings

c. Failed

components

a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service

16.Noisy

operation

a. Mounting area not firm
b. Loose

parts



c. Compressor overloaded due to

high ambient temperatures or
airflow restriction

d. Defective

components

a. Add support to improve installation
b.

Check fan blades, bearings,
washers, tubing contact and loose
screws.

c. Check for airflow


d. Call service for checking internal

loose, inadequate lubrication and
incorrect wirings












Advertising