Code 93, 2 of 5 code, 2 of 5 data length – Worth Data P11/12 User Manual

Page 11

Advertising
background image

2-5

Code 93

Enable

0

Disable

1

Enable Full ASCII

2

Disable Full ASCII

3

For more information about Code 93, See Appendix J

2 of 5 Code

Enable Interleaved 2 of 5

0

Disable Interleaved 2 of 5

1

Enable Interleaved 2 of 5 check digit

2

Disable Interleaved 2 of 5 check digit

3

Enable check digit transmission

4

Disable check digit transmission

5

Enable Standard 2 of 5

6

Disable Standard 2 of 5

7

For information about Interleaved 2 of 5, see Appendix F.

Enabling the check digit requires that the data’s units position (last character) match the
calculation for the check digit explained in Appendix F. If you have enabled the check digit
and want to transmit the check digit to the computer along with the rest of the bar code
data, choose “Enable check digit transmission”.

2 of 5 Data Length

Default Length

06

2 of 5 Code is so susceptible to interpreting partial scans as valid reads that the
WDP Reader uses fixed-length data as a safeguard. To choose a data length, scan
it as a two-digit number using the Barpad Table. For example, to select 8-digit data
length, you would scan a 0 and then a 8. Because Interleaved 2 of 5 is required to
be an even number of digits in length, you must use an even number. If you're
unsure of your bar code length, temporarily set length to 00, read a bar code, and
count its digits. Variable-length 2 of 5 codes are not recommended.

bar codes in ISBN format (the nine ISBN digits plus a new calculated mod-11
check digit), scan Terminator Character and 11D. Scanning C, the default,
disables conversion to ISBN format.