Problem

Possible Cause

Solution

15. Brine tank overflow.

a. Brine valve disc 1 held open.

b. Valve disc 2 not closed during brine

draw, causing brine refill.

c. Air leak in brine line to air check.

d. Salt setting too high.

a. Manually operate valve stem to flush

out foreign matter holding disc open.

b. Manually operate valve stem to flush

out foreign matter holding disc open.

c. Check all connections in brine line for

leaks.

d. Set in new values. Refer to

Programming section in this manual.

16. System using more or

less salt than salt
setting.

a. Inaccurate setting.

b. Foreign matter in salt controller

causing incorrect flow rate.

c. Defective circuit board.

a. Correct salt setting. Refer to the

Programming section in this manual.

b. Manually position control to BRINE/

SLOW RINSE to clean controller.

c. Replace control.

17. Intermittent or irregular

brine draw.

a. Low water pressure.

b. Defective injector !

a. Increase water pressure (20 psi at

conditioner).

b. Replace both injector and injector cap.

18. No conditioned water

after regeneration.

a. Unit did not regenerate.

b. No salt in brine tank.

c. Plugged injector !

d. Air check valve closed prematurely.

a. Check for power.

b. Add salt to brine tank.

c. Remove injector and flush it and

injector screen.

d. Put control momentarily into REFILL to

free air check. Replace or repair air
check if needed. Refer to instructions.

19. Control backwashes at

excessively low or high
rate.

a. Incorrect backwash controller !

b. Foreign matter affecting controller

operation !

a. Replace with correct size controller.

b. Remove and clean controller and ball.

20. Flowing or dripping

water at drain line or
brine line after
regeneration.

a. Drain valve (5 or 6) or brine valve (1)

held open by foreign matter.

b. Weak valve stem return spring on

top plate.

c. Resin in valve.

a. Manually operate valve stem to flush

out foreign matter holding disc open.

b. Replace spring.

c. Clean valve and backwash control.

21. Hard water leakage

during service.

a. Improper regeneration.

b. Leaking of bypass valve !

c. O-ring around riser tube

damaged !

a. Repeat regeneration making sure that

the correct salt dosage is used.

b. Replace O-ring.

c. Replace O-ring.

Table 6 - Troubleshooting Procedures