Water Boss Series 255 User Manual

Page 9

Advertising
background image

9

Note:

If the calculation for the system capacity

exceeds 9999 gallons (99.99 cubic meters) (P5,
Capacity, divided by P3, Hardness,) the control will
display 9999 (99.99) for capacity until the water usage
has dropped the remaining capacity below that
number. When water is flowing through the system, the
colon in the Time of Day display will blink.

At this time, all of the mandatory parameters are filled
and the control is ready for operation. The display will
alternate between the Time of Day and Capacity if no
keys are pressed for 30 seconds. The Capacity value is

the volume remaining in gallons (cubic meters for
metric) before a regeneration is needed.

Verify proper power outage operation by briefly
removing power to the control. The unit will beep and
show the time of day when power is turned on.

If you wish to fine-tune the operation of this control,
refer to Table 3 for details concerning allowable values,
defaults, and parameter descriptions. The
programming procedure is the same for all of these
parameters.

Table 1 - Programming Parameters

Parameter

Range of

Values

Minimum

Increments

Default

Units of

Measure

Notes

Name

Description

P1

Time of day

AM or PM

1:00 to 12:59

00:00 to 23:59

1

None

Hour:minute

Range depends on value

selected for P13. Enter the

current time.

P2

Time of day

of

regeneration

1:00 to 12:59

AM or PM

00:00 to 23:59

1

2:00 AM

Hour:minute

Range depends on value

selected for P13. Skip this

parameter to accept the

default or enter a new time.

P3

Hardness of

water

3 to 250

30 to 2500

1

10

10

100

Grains/gallon

mg/L

Unit of measure depends on

value selected for P12. Test

water hardness and enter

that value.

P4

Salt amount

0.5 to 99.5

0.1 to 25.5

0.5
0.1

6

2.5

Pounds

Kilograms

Unit of measure and default

depends on value selected

for P12. Refer to Table 2.

P5

Capacity of

unit

0.1 to 140.0

0.01 to 14.00

0.1

0.01

1.0

0.1

Kilograins

Kilograms

Unit of measure depends on

value selected for P12. Enter

the unit capacity.

Table 2 - Suggested Salt Settings

(Pounds of Salt for Various Size Conditioners)

Resin Bed Volume

Kilograins of

Hardness

Capacity

Setting

0.5 ft

3

0.75 ft

3

1.0 ft

3

1.25 ft

3

1.5 ft

3

1.75 ft

3

2.0 ft

3

12

4.5

-

-

-

-

-

-

16

9.0

5.0

-

-

-

-

-

20

-

8.5

6.0

-

-

-

-

24

-

14.0

8.5

7.0

-

-

-

30

-

-

15.0

11.0

9.0

-

-

32

-

-

18.5

12.5

10.0

9.0

-

35

-

-

-

16.0

12.0

10.0

9.0

40

-

-

-

23.0

17.0

14.0

12.0

48

-

-

-

-

28.0

21.0

17.0