Installation, Conversion kit from natural gas to propane, Gas pipe pressure testing – Waterford Appliances E65-NG1 User Manual

Page 25

Advertising
background image

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

25

4) Carefully remove the logs, embers and

rockwool.

5) Remove burner. See diagram below.

Pilot assembly is now accessible

for steps 6) to 11).

Note: Use a magnetic type screwdriver

if possible.

THIS CONVERSION MUST

BE DONE BY A

QUALIFIED GAS

FITTER IF IN DOUBT DO

NOT DO THIS

CONVERSION !!

3) Open the front door. Open the right side

door and there is a cutout in the heat shield
through which can be seen a wing nut
threaded on to a stud attached to the front
door. Loosen this nut by turning it counter-
clockwise.

Conversion Kit Contains:

Qty.

Part # Description

1

910-018

SIT Conversion Kit-50%
Turndown LP

1

910-037

LP Injector (Pilot Orifice)

1

904-641

Burner Orifice #50

1

908-175

E63/E65 Decal "Converted to
Propane"

1

908-528

Red "PROPANE" label

1

908-780

Instruction Sheet

1) Shut off the gas supply.

2) Open the valve door and remove the control

panel.

CONVERSION KIT

FROM NATURAL GAS

TO PROPANE

Model #261-969

for Emerald Gas Stoves and Gas

Inserts using SIT 820 NOVA Gas

Valve

INSTALLATION

GAS PIPE

PRESSURE TESTING

The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnect piping from valve at pressures
over 1/2 psig.

The manifold pressure is controlled by a regu-
lator built into the gas control, and should be
checked at the pressure test point.

Note: To properly check gas pressure,

both inlet and manifold pressures
should be checked using the valve
pressure ports on the valve.

1) Make sure the valve is in the "OFF" position.

2) Loosen the "IN" and/or "OUT" pressure tap(s),

turning counterclockwise with a 1/8" wide
flat screwdriver.

3) Attach manometer to "IN" and/or "OUT" pres-

sure tap(s) using a 5/16" ID hose.

4) Light the pilot and turn the valve to "ON"

position. Read manometer.

5) The pressure check should be carried out

with the unit burning and the setting should
be within the limits specified on the safety
label.

6) When finished reading manometer, turn off

the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
flat screwdriver. Note: Screw should be
snug, but do not over tighten

Valve Description

1) Gas cock knob

2) Manual high/low adjustment

3) Pilot Adjustment

4) Thermocouple Connection

5) Main Operator

6) Outlet Pressure Tap (Manifold Pressure)

7) Inlet Pressure Tap (Supply Pressure)

8) Pilot Outlet

9) Main Gas Outlet

10) Flange Securing Screw Holes

11) Alternative TC Connection Point

12) Thermoelectric Unit

13) Additional Valve Mounting Hole