Maintenance, Removing valve, Installing valve assembly – Waterford Appliances E65-NG1 User Manual

Page 33

Advertising
background image

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

33

11) Carefully lift the burner tray assembly out.

REMOVING VALVE

If your valve requires maintenance or replace-
ment, use the following instructions:

Note: Always close off the gas supply

before removing the valve.

1) If optional fan is installed, disconnect pow-

er source to stove.

2) Remove access panel.

3) Unclip the black and white wires from the

fan motor.

4) Lift fan off of the 2 pins, tip back and pull

through rear panel. Do not tear or damage
the flex pipe when removing the fan. Dis-
connect the green ground wire from the
right side of the fan as soon as you can
reach it.

Replacing the Fan:

Reverse the above steps (1 - 4). Make sure the
fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit
of dish soap on the grommet so it will slide
more easily onto the pin. Check to make sure
the fan is seated properly on the pins - try to
move the fan back and forth, there should be
no noise, if there is check that the grommets
haven't come loose.

3) Disconnect gas line to stove.

4) Disconnect 3/8" NPT pipe from 90

o

elbow on

valve.

5) Disconnect the two (2) switch wires from

valve.

6) Disconnect piezo wire.

7) Open the front door. Disconnect the front

door from the safety mechanism located on
the right side of the heater. Open the right
side door and there is a cutout in the heat
shield through which can be seen a 1/4" nut
threaded on to a stud attached to the front
door. Loosen
this nut by turn-
ing it counter-
clockwise with
a 3/16" wrench
until it can be re-
moved by hand.

8) Carefully remove the logs, embers and

rockwool.

9) Remove burner. See diagram below.

Note: Use a
magnetic type
screwdriver if possible.

12) To replace the burner tray assembly, simply

reverse these instructions.

To remove valve from valve assembly,
continue.

13) Remove two (2) thermopile wires.

14) Remove thermocouple with a 9 mm (metric)

wrench.

15) Remove pilot nut with an 11 mm wrench.

16) Remove valve to orifice nut with a 13/16"

wrench.

17) Remove inlet pipe with pipe wrench. Note

orientation of 90

o

elbow.

18) Remove two (2) phillips head M5 screws on

each side of the valve.

19) Remove valve and remove gas out 90

o

brass fitting. Note orientation of fitting.

INSTALLING VALVE

ASSEMBLY

1) To install a new valve assembly, reverse

instructions for removing valve . See
assembly steps 1-12.

2) Check for leaks and manifold pressure. See

Gas Pressure Test instructions.

3) To reinstall valve, reverse instructions for

removing valve assembly, steps 13-19.

To remove fan:

1) Unplug or disconnect power source to

stove.

2) Remove the 6 screws holding the access

panel in place.

MAINTENANCE

10) Remove all 18 screws holding the burner

tray assembly in place.

IMPORTANT

Disconnect power supply

before servicing

Advertising
This manual is related to the following products: