Caution – White Rodgers 1F97W-71 User Manual

Page 15

Advertising
background image

15

the selected setting until you press

RUN

PRGM

to

start program operation again. This feature is
ideal for energy conservation when the build-
ing is unoccupied for an extended period of
time.

°

F/

°

C CONVERTIBILITY — Press

TIME

FWD

and

TIME

BACK

at the same time until the temperature

display is in

°

C (Celsius). To display

°

F, repeat

the process.

ADJUSTABLE HEATING AND COOLING

CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.

A cooling anticipation setting of less than
10 may cause decreased compressor life.

To adjust heat anticipation, press

SET

CLOCK

and

ADV

DAY

at the same time. The display will show

HEAT 5 (this is the factory preprogrammed
heating anticipation setting). You may select
any anticipation setting from 4 to 40 (note
that for hydronic systems, a minimum an-
ticipation setting of 15 is recommended
).
Whenever adjusting anticipation, increase or
decrease the displayed number by only one
or two digits, then let the system run for a while
to see if the adjustment is sufficient. If the heat

cycles are too short, press

TIME

FWD

to increase

the cycle time. If the heat cycles are too long,

CAUTION

!