FEATURES & OPERATING CONTROLS (continued)

3

ITEM

1.

5.

a6.


8.

9.

a10.

a11.

12.

a15.

16.

18.

19.

22.

28.

a31.

38.

41.

42.

43.

44.

53.

56.

57.

58.

DESCRIPTION

NAMEPLATE

APPLIANCE LIGHT

FIRE SUPPRESSION
AGENT TANK (1.5 gal.)

ADJUSTABLE (FRONT) LEG

RIGID (REAR) CASTER

MANUAL PULL STATION

FUSIBLE LINKS

LOWER REAR ACCESS
PANEL

DISCHARGE NOZZLE

GREASE BAFFLE

PRE-FILTER ASSEMBLY

HI-EFFICIENCY/CHARCOAL
FILTER PACK

GREASE DRIP TRAY

VENTILATOR EXHAUST
DUCT

STATUS INDICATOR

POWER CORD

POWER CONTACTOR

BUILDING FIRE ALARM
RELAY

GROUND LUG

INTERLOCK TERMINAL

FILTER INTERLOCK
SWITCHES

VENTILATOR FAN

HOOD SIDE SHIELD

SIDE SPACERS

COMMENT

Gives manufacturer, make and model description. Also lists voltage
and amperage data.

ON when hood power switch is ON. Illuminates cooktop.

Container for Ansulex™ Low-pH liquid fire suppression liquid.

Allows the unit to be leveled.

Allows the unit to be easily positioned by lifting the front of the unit
slightly.

Provides a means of manual activation of the fire suppression system.
PULL ONLY IN CASE OF FIRE!

Designed to break at rated temperature. Breaking (i.e. fire on the
cooktop) activates fire suppression system. Should be replaced at
least once per year.

Allows access to Ansul® fire suppression agent tank (a6) and controls
also access to main power contactor (41).

Fire suppression media discharges here (2 places).

Extracts and drains most grease and moisture from the air flow.

Comprises the PRE-FILTER FRAME and a replaceable
PRE-FILTER. Stops larger particles of grease from reaching the
FILTER PACK for reduced maintenance costs.

Stops most grease and smoke particles. Also assists in some cooking
odor removal.

Collects grease/moisture dripping from grease baffle(16).

Exit point for ventilator airflow - on top left rear of unit.
DO NOT BLOCK

Displays status of fire suppression system (COCKED - FIRED) If
FIRED, a buzzer will sound continuously.

6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).

Energizes cooking appliances only while ventilator section is sensed
as operational.

Reports fire alarm condition to building fire management system.

Ground wire of power cord connects here.

Provides connection for shut-down control by building fire management
system.

Proper installation of grease baffle and filter pack close these switches
in ventilator sensor circuit.

Provides air movement for ventilation.

Required on left and right sides of hood. Factory installed.

Required to maintain 6" spacing from combustibles. Field installed.

VENTILATOR SECTION