Initiating the Appliance

For your safety, read before operating.

WARNING: If you do not follow these
instructions exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.

a) This appliance does not have a pilot. It is

equipped with an electronic ignition device,
which automatically lights the burner. Do
not try to light the burner by hand.

b)

Before operating, check for gas
accumulation in the area around the
appliance. Pay special attention near the
floor, because gas is often heavier than air,
and it may accumulate near the floor.

c) Do not attempt to open the manual gas

shutoff valve with anything but by hand.
Never use tools. If the valve will not open
by hand, do not try to repair it. Instead, call
a qualified service technician. Force or
attempted repair may result in a gas leak,
fire or explosion.

d) Do not use this appliance if any part has

been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part that may
have been damaged by being under water.


WARNING: IF YOU SMELL GAS:

Do not use any appliance.

Do not touch any electric switch, do not

use any phone in your building.

Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

If you cannot reach your gas supplier, call

the fire department.











Initial Operation


1. STOP! Do not operate without reading the

safety information first!

2. Switch off the electrical power supply to the

heater.

3. Do not attempt to light the burner manually.
4. Turn the manual gas control valve located

on the outside of the unit counterclockwise
to the OFF position.

5. Wait five (5) minutes to clear out any gas.

If you then smell gas, STOP! Follow “b” in
the “Initiating the Appliance” section above.
If you do not detect gas, proceed to the
next step.

6. Turn the manual gas control valve located

on the outside of the unit clockwise to the
ON position.

7. Turn on the electrical power to the

appliance.

8. Turn on any tap, and the T-K2 will initiate

itself.

9. If the appliance will not operate, follow the

instructions in the “Turning Off the Gas
Supply to the Appliance” section following,
and call a service technician or gas
supplier.


TURNING OFF THE GAS SUPPLY TO THE
APPLIANCE

Close the manual valve on the gas inlet line.
Turn off the power supply.

Manifold pressure tap.