Computer board – Whirlpool T-K2 User Manual

Page 22

Advertising
background image


The T-K2 Will Not Initiate
First check the flow rate through the unit. If the flow is not .75 GPM or greater, the unit will not
initiate. Check the filter and the flow sensor for any debris or damage.
Press the lower green button on the GFCI inside the unit. If the red light above it does not come on,
then there is a problem with the electrical supply to the unit. If that light does come on, hit the green
reset button above the light, and look for the green light on the circuit plate at the top left of the unit.
If this light is not lit, there is a problem with the electrical connection between the GFCI and the
circuit plate. Contact Takagi Industrial Company for Instructions.
Error Codes
All Takagi units are self diagnostic for errors. If there is a problem with the installation or the unit, it
will give a signal, through a pair of flashing lights on the circuit plate, to communicate the source of

the problem. If the unit has a TK-RE01 remote control installed, this
will give also give a numerical error code. Consult the following chart
for the meaning of an error code:












TK-RE01

Computer Board

TK-RE01 Check

Point

11 Igniter
12 Flame

Detector

51 Main

Gas

Valve

Burning (red) LED: Blinking

Power (green) LED: OFF

72 Pre

Post

Check

03

Wrong Gas, Dip Switch

14 Hi-Limit

Switch

70 Computer

Board

Burning (red) LED: OFF

Power (green) LED: Blinking

71 Proportional

Valve

61 Fan

Motor

Burning LED and Power LED:

Blinking Alternately

21 Vent

Pipe

31 Thermistor

Burning LED and Power LED:

Blink Simultaneously

65 Water

Control

Valve



For technical support contact Takagi toll free at (888) 882-5244, or check our

website at www.takagi-usa.com.



Advertising