Troubleshooting suggestions – Wells WVF-886 User Manual

Page 26

Advertising
background image

TROUBLESHOOTING SUGGESTIONS

DESCRIPTION

Ventilator blower won’t run

Ventilator blower won’t
run — buzzer sounding

Ventilator blower runs
momentarily, shuts down.




CHECK FILTERS light on

REPLACE PREFILTER
light on.

REPLACE FILTER PACK
light on

SERVICE REQUIRED
light on


Roll warmers won’t heat
(ventilator operational)

Warmer drawer not hot
enough

Product in warmer drawer
too dry or wet

POSSIBLE CAUSE

Circuit breaker tripped

Ansul® fire suppression system
tripped

Clogged filter , or filter out of position


Damaged internal components


Filter or grease baffle out of position

Pre-filter clogged, but still operational


Filter pack clogged, but still
operational

Prer-filter or filter pack clogged



Damaged internal components


Temperature control not set


Humidity control not set

SUGGESTED ACTION

Check / reset circuit breaker

Contact Authorized Ansul®
Distributor for repairs

Observe indicator lights,
service filter(s) as required

Contact your Authorized Wells
Service Agent for repairs

Reinstall filters / baffle

Replace pre-filter at first
opportunity

Replace filter pack at first
opportunity

Replace pre-filter first. If
indicator stays lit, replace filter
pack

Contact your Authorized Wells
Service Agent for repairs

Set control to desired temp


Set for desired humidity

NOTE: There are no user serviceable components in the appliance.
A. In all cases of damage or component malfunction, contact your Authorized Wells Service Agency for
repairs.
B. For service of the fire suppression system, contact an Authorized Ansul® Distributor.