Electrical connection – Zanussi ZC 605 M User Manual

Page 17

Advertising
background image

71

ELECTRICAL CONNECTION

The unit is preset to work with a voltage of single phase
230 V.
Before making the connection make sure that:
— the energy power available in the user's house is

sufficient for the normal supply of this appliance
(see rating plate).

— the unit is correctly connected to earth through a

suitable plug and according to the installation
country Laws.

— the socket or the omnipolar switch used for the

connection must be easilv reached with the installed
appliance.

The appliance is supplied without electric cord:
consequently, you have to install a plug fit for the load
shown in the serial number plate. The plug has to be
connected to an adequate socket.
If you wish to directly connect to the mains, you have
to interpose an omnipolar switch with a minimum
opening between contacts of 3 mm, between the unit
and the mains, complying with the existing regulations.
The brown live wire (originating from the clamp of the
cooker junction box) must always be connected to the
phase of the mains supply. In any case, the supply cord
must be positioned in such a way as it doesn't reach in
any point a temperature higher by 50

°

C than the room

temperature.
Should the supply cord need to be replaced, use only
type H05RR-F cables. It is necessary that the yellow/
green earth wire is about 2cm longer than the live and
neutral ones (Fig. 17).
After the connection, test the heating elements for
about 3 minutes to ensure that they are working
correctly.

The manufacturer refuses any responsability in
cases where normal safety measures are not
observed.

Ground (yellow - green)

Neutral
wire

Phase

FO 0480

Fig. 17

Advertising