Problem solving – Xantrex Technology XC1524 User Manual

Page 65

Advertising
background image

Problem Solving

975-0187-01-01

4–7

Problem Solving

If the remote display is not functioning, troubleshoot your XC Series using the
tables below. In the event that you have a problem with your XC Series, the
following tables will help you to identify the problem and offer possible solutions to
the problem.

Symptom

Indicator lights do not illuminate when charger is connected to AC power.

Symptom

Fault indicator light illuminates. XC Series stops functioning.

Possible Cause

Solution

No power at AC source and no
battery connected on bank 1

Defective AC wiring

Charger level fault

Ensure that power is available at the source and a
battery or bank is connected on bank 1

Replace wiring

Call for service

Possible Cause

Solution

XC Series does not detect battery
for one of following reasons:

poor connection

reverse polarity connection

damaged wiring

XC Series internal temperature
too hot

Check quality of battery connection and wires.
Ensure correct polarity (negative connected to
negative, positive connected to positive).

Allow the XC Series to cool. Improve ventilation or
install in cooler location.

XC_Charger_Owner.book Page 7 Friday, August 12, 2005 3:23 PM