Yamaha D5000 User Manual

Page 36

Advertising
background image

MIDI Data format - 103

D5000

Checksum

0eeeeeee

EOX

11110111

(

F7H

)

3 System Set-up Bulk Data
When a MIDI BULK DUMP operation is performed with the "SYSTEM" ITEM selected or when a System
Set-up Bulk Data Request message is received, the data is transmitted on the currently set MIDI channel.

Status

11110000

(

F0H

)

ID Number

01000011

(

43H

)

Sub Status

0000nnnn

(

0nH

)

n = 0 (channel number1) ~ 15 (channel number 16)

Format Number

01111110

(

7EH

)

Byte Count (MSB)

00000000

(

00H

)

Byte Count (LSB)

00010101

(

15H

)

Header

01001100

(

4CH

)

ASCII “L”

01001101

(

4DH

)

ASCII “M”

00100000

(

20H

)

ASCII “ ”

00100000

(

20H

)

ASCII “ ”

00111000

(

38H

)

ASCII “8”

01000001

(

41H

)

ASCII “A”

00110110

(

36H

)

ASCII “6”

00110011

(

33H

)

ASCII “3”

Data Name

01010011

(

53H

)

ASCII “S”

00100000

(

20H

)

ASCII “ ”

Soft Version Number

0vvvvvvv

v = 1

0rrrrrrr

r = 0

Data

0ddddddd

...

9 Bytes

0ddddddd

Checksum

0eeeeeee

EOX

11110111

(

F7H

)

4 Parameter Change
When a Parameter Value Request message is received, the parameter data is transmitted on the currently set
MIDI channel.

Status

11110000

(

F0H

)

ID Number

01000011

(

43H

)

Sub Status

0001nnnn

(

1nH

)

n = 0 (channel number1) ~ 15 (channel number 16)

Group/Sub Group

00011110

(

1EH

)

Device Code

00000011

(

03H

)

Parameter Number

0nnnnnnn

1st byte

0nnnnnnn

2nd byte

Parameter Data

0ddddddd

...

8 bytes

0ddddddd

EOX

11110111

(

F7H

)

5 All Bulk Data
When a MIDI BULK DUMP operation is performed with the "ALL" ITEM selected, the data is transmitted
on the currently set MIDI channel. All program data, all program change bank data, and all system set-up
data will be transmitted in the following order:

1 Program Bulk Data - program

1

to program

00

(100

)

2 Program Change Bank Bulk Data - bank

A

to bank

B

3 System Set-up Bulk Data

Advertising