Ignition system / gas ignition – Zanussi ZGL 62 ITX User Manual

Page 14

Advertising
background image

14

Ignition System / Gas Ignition

YES

Check plug top fuse
and
replace if necessary

Check polarity and
earth continuity of
supply point

Check earth continuity
of appliance

Ignitor does not spark

Check fitting of burners

Check position of the
electrode

Check by pass
simmer

Light burner manually

Check gas supply at
burner

Check continuity from 'N' on the
mains connector block and "O" on
the ignitor unit

Check continuity from 'L' on the
mains connector block and the
taps ignition switches

Check continuity from ignition
switches connector to ignitor unit

Check continuity from the tip
of each electrode to the
terminals 1 to 4 on the ignitor
unit

Check for breaks in the
insulation
of the HT leads

Change the taps
ignition switches

NO

Change the ignitor unit

Advertising