Instructions for the installer, Engineers technical data, Overall dimensions – Zanussi ZGL 62 ITX User Manual

Page 8: Cut out dimensions, Supply connections

Advertising
background image

8

Rear Left Burner

(semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner

(auxiliary)

Heat Input

1.0 kW (3412 BTU/HR)

Rear Right Burner

(semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner

(rapid)

Heat Input

3.0 kW (10236 BTU/HR)

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

580 mm

Depth:

500 mm

Cut out dimensions

Width:

550 mm

Depth:

470 mm

Supply connections

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230 V 50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL
POWER kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW
RATE m

3

/h

0.286

0.062

0.190

0.043

0.095

0.031

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

NOMINAL THERMAL
POWER kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW
RATE g/h

202

47

144

32

72

24

NOZZLE REFERENCE

86

40

71

32

50

28

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

NATURAL GAS

20 mbar

TYPE OF

GAS

Characteristics

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

APPLIANCE CLASS:

3

APPLIANCE CATEGORY:

II2H3+

APPLIANCE GAS SUPPLY:

Natural gas G20/20 mbar

Advertising