FLEXIBLE PIPE INSTALLATION

FITTING THE APPLIANCE AND CABINET
It is recommend that a

3

/8", 1100mm long

angled flexible hose (BFS), and a ½ " straight
socket (BFS) be used for the installation.
However, any approved hose of the right length
can be used.
IMPORTANT:Flexible tubing used must comply
with BS 669 current editions. L.P.G. flexible
connections must be of a type suitable for
L.P.G. and capable of operation up to 50mbar
and carry a red stripe, band or label.
NOTE: Only liquid sealants can be used in
threaded gas connections. Do not use P.T.F.E.
tape.
1

Make suitable arrangements for gas and

electric supplies into the installation site.

2

When unpacking the appliance keep it on
its polystyrene base until it is put into the
cabinet to avoid damage.

3

If the gas supply bayonet and wall fixing
bracket are to be located behind the
appliance it must be located in the shaded
area as indicated in Fig.8.

4

Connect flexible hose to the gas inlet supply
block see Fig.8. The hose should be long
enough to allow the appliance to be
withdrawn from the cabinet.

5

Position the appliance in front of the cabinet

and run the supply cable (See Connection
to Electricity Supply) through the cabinet
and connect to the junction box or socket.
Ensure that the supply is isolated at this
stage. Connect flexible hose to the bayonet
connector.

43

INSTALLATION INSTRUCTIONS

Fig.8

120

120

580

280

Advertising